Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rom J Ophthalmol ; 67(1): 62-68, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37089803

RESUMO

We aimed to test a novel concept based on multiple IOL-implantation, targeting spectacle independence for patients with high and excessive myopia (26.0 mm < axial length; 6.0 D < refractive error). Therefore, we introduced the first results of five patients with high myopia. After clear lens extraction, one eye was targeted to emmetropia, and the other to mild myopia by implanting monofocal capsular bag IOLs with appropriate refractive powers in each case. The emmetropic eye was aimed to result in magnification and improved distance vision, while the mild myopic eye was supposed to ensure good intermediate vision. Thereafter, a Scharioth Macula Lens (SML) was implanted into the emmetropic eye in order to achieve sharp near vision. Visual acuity curves and defocus curves were plotted postoperatively. According to our results, this new concept seems to be an efficient approach of achieving appropriate uncorrected vision at all distances, by creating binocular trifocal monovision.


Assuntos
Lentes Intraoculares , Miopia , Humanos , Óculos , Visão Monocular , Acuidade Visual , Miopia/cirurgia , Desenho de Prótese , Visão Binocular , Satisfação do Paciente
2.
Rom J Ophthalmol ; 66(3): 225-232, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36349177

RESUMO

The modern glaucoma surgeon is faced with many surgical alternatives for the management of glaucoma. In recent years, numerous techniques that make Schlemm's canal (SC) more accessible for surgery by being less invasive and surgically less challenging were introduced. Since its first introduction, canaloplasty has become a well-established method of glaucoma surgery. The aim of this paper was to present an overview of canaloplasty and its modifications, and to highlight their strong points and potential drawbacks based on available data on the effectiveness of each technique. Furthermore, it offered an overview of the development of canaloplasty over time and the clinical aspects that should be considered in patient selection. Abbreviations: ABiC = Canaloplasty ab interno, AH = aqueous humour, CSD = Canaloplasty with suprachoroidal drainage, IOP = intraocular pressure, MIGS = minimally invasive glaucoma surgery, OAG = open angle glaucoma, PEXG = pseudoexfoliation glaucoma, SC = Schlemm's canal, TDM = trabeculo-Descemet's membrane.


Assuntos
Síndrome de Exfoliação , Cirurgia Filtrante , Glaucoma de Ângulo Aberto , Glaucoma , Humanos , Glaucoma de Ângulo Aberto/cirurgia , Cirurgia Filtrante/métodos , Pressão Intraocular , Humor Aquoso , Glaucoma/cirurgia
3.
Rom J Ophthalmol ; 66(2): 135-139, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35935089

RESUMO

Objective: To compare the number of surge events and efficacy of phacoemulsification using a near-physiological intraocular pressure (IOP) setting and a standard IOP setting. Materials and methods: The surgical data of patients who underwent phacoemulsification with IOL implantation using the CENTURION Vision System's Active Fluidics setting and Active Sentry Handpiece (Alcon Laboratories, USA) were analyzed. Results: The study included 181 patients (204 eyes). In Group 1, the IOP was set at 20 mmHg (n=102, 50%), and in Group 2, the IOP was set at 60 mmHg (n=102, 50%). Total case time was significantly lower (p=.036) in Group 1 (0:03:17.20 ± 0:00:34.55 vs. 0:03:28.71 ± 0:00:43.03). There was no statistically significant difference between the mean cumulative dissipated energy (CDE) (7.06 ± 3.20 vs. 7.59 ± 3.26) and mean ultrasound (UJS) time (0:00:36 ± 0:00:12 vs. 0:00:38 ± 0:00:13) between the two groups (p=0.24 and p=0.31, respectively). Active sentry (AS) engaged less often (p<0.001) in Group 1. There was no statistically significant correlation between the CDE and AS activation in Group 1 (p=0.96). A strong statistically significant correlation between the CDE and AS activation (p<0.0001, r=0.61, CI (0.47 to 0.72)) was observed in group 2. Conclusion: During phacoemulsification, surge events are more likely to occur when operating at high IOP settings. Abbreviations: LIPMICS = low infusion pressure microincision cataract surgery, IOP = intraocular pressure, CDE = cumulative dissipated energy, UJS = mean ultrasound time, AS = Active sentry, LOCS = Lens Opacities Classification System, NO = nuclear opalescence, AFR = aspiration flow rate.


Assuntos
Extração de Catarata , Catarata , Facoemulsificação , Humanos , Pressão Intraocular , Implante de Lente Intraocular , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...